| MODEL No. | SR300-112 | RS300-124 | RS300-212 | RS300-224 | |
| AC VOLTAGE | 100 / 110 / 120 VAC | 220 / 230 / 240 VAC | |||
| RATED POWER | 300W | ||||
| SURGE POWER | 400W | ||||
| WAVEFORM | True sine wave (THD < 6%) | ||||
| FREQUENCY | 50 / 60 Hz | ||||
| OUTPUT | AC REGULATION | ±5% | |||
| POWER FACTOR ALLOWED | COSq-90 ~ COSq+90 | ||||
| STANDARD RECEPTACLES | NEMA5-15R / GFCI | Schuko / UK / Australia / universal | |||
| LED INDICATOR | Input voltage level, output load level and fault status | ||||
| NO LOAD CURRENT DRAW | 0.24A | 0.28A | 0.26A | 0.28A | |
| DC VOLTAGE | 12VDC | 24VDC | 12VDC | 24VDC | |
| INPUT | VOLTAGE RANGE | 10.5~15.0VDC | 21.0~30.0VDC | 10.5~15.0VDC | 21.0~30.0VDC |
| EFFICIENCY (Typ.) | 89.0% | 89.0% | 89.0% | 89.0% | |
| FUSE | 40A x 1 | 25A x 1 | 40A x 1 | 25A x 1 | |
| REMOTE CONTROL | By external switch | ||||
| BAT. LOW SHUTDOWN | 10 A0.5V | 20 A1.0V | 10 A0.5V | 20 A1.0V | |
| OVER LOAD | Shut off output voltage, re-power on to recover | ||||
| PROTECTION | OVER VOLTAGE | 15 ~ 16VDC | 30 ~ 32VDC | 15 ~ 16VDC | 30 ~ 32VDC |
| OVER TEMPERATURE | Shut off output voltage, recovers automatically after temperature goes down | ||||
| OUTPUT SHORT | Shut off output voltage, re-power on to recover | ||||
| BAT. POLARITY REVERSE | By fuse open | ||||
| WORKING TEMP. | 0 ~ +40BC | ||||
| ENVIRONMENT | WORKING HUMIDITY | 20% ~ 90% RH non-condensing | |||
| STORAGE TEMP. & HUMIDITY | -30BC ~ +70BC / -22BF ~ +158BF / 10 ~ 95% | ||||
| SAFETY STANDARDS | UL458 (only for "GFCI" receptacles) | ----- | |||
| ISOLATION RESISTANCE | I/P ~ O/P: 100M Ohms / 500VDC | ||||
| EMI CONDUCTION & RADIATION | Compliance to FCC class B | ||||
See more products from this supplier.